Frequency Calibrator/Counter
Pendulum CNT-90 Basic Frequency Counter/Analyzer
The CNT-90 Frequency Timer/Counter/Analyzer is excellent for measurement, analysis and calibration of frequency, time, or phase. In production test systems, R&D, the calibration lab, or in the field; the CNT-90 timer/counter/analyzer outperforms many existing counters on the market.
Fluke 96270A 27 GHz Low Phase Noise Reference Source
The Fluke Calibration 27 GHz 96270A RF Reference Source is the simplest, most accurate and cost effective single instrument for calibrating spectrum analyzers and RF power sensors and more.
Pendulum CNT-91 Timer/Counter/Analyzer
The CNT-91 provides high 50 ps single shot time resolution or 12 digits/sec frequency resolution for capturing very small time and frequency changes. And, displays up to 14 digits on values obtained.
Pendulum TimeView™ Modulation Domain Analyzer Software to 20 GHz
The TimeView™ modulation domain analysis software for Windows converts the CNT-90-family Timer/Counter/Analyzer to a high performance MDA (Modulation Domain Analyzer) with a frequency range up to 20 GHz.
Pendulum 6688/6689 High Stability Frequency Standards
Rubidium or high stability oven frequency reference standard
Distribution amplifiers for 5x10 MHz and 1x5 MHz outputs as standard
Optional 10x10 MHz outputs
0.001 ppm aging in 10 years (Rubidium)
BK Precision 1856D 3.5 GHz Multifunction Counter (Frequency, Period, Totalize)
The model 1856D provides versatility and reliability for a broad spectrum of laboratory and service applications. Wide measuring range up to 3.5GHz nine digit LED display.
BK Precision 1823A เครื่องวัดความถี่ 2.40Hz สำหรับงานทั่วไปพร้อมฟังก์ชั่น Ratio
จอแสดงผล LED สว่างชัดเจน
มีฟังก์ชั่น Trigger
วัดอัตราส่วนความถี่ได้ (Frequency ratio)
วัดช่วงเวลาได้ (Time interval)
Pendulum DA-36 Fiber&Coax Frequency Distribution
The Distribution Amplifier DA-36 solves the problem of distributing a reference frequency from a central frequency standard to one or several receiving points.
Pendulum GPS-12R GPS-Controlled Frequency Standard
Long-term frequency stability is provided from the built-in Cesium-controlled standards in the GPS-satellite. Very high short-term stability comes from the built-in oven controlled crystal oscillator found in the GPS-88; or the built-in Rubidium atomic clock installed in GPS-89, as its local oscillator.
Fluke 910R GPS Controlled Frequency Standards
The cesium controlled frequency standard that uses GPS technology and connectivity to provide primary standard traceability from any location